Copper Sheath Immersion Element
With 2" N.P.T. Brass Screw Plug-Silver Brazed
- For Water - 60 Watts Per Square Inch
- With 3/8" ID Copper Thermowell
- Regulated (Single Pole Stat) and Non-Regulated
KW | Volts | Phase | Dimensions (Inches) |
Non-Regulated | Regulated (60°-250°F) | |||
General Purpose Enclosure |
Moisture/Explosion Resistant Enclosure |
General Purpose Enclosure |
Moisture/Explosion Resistant Enclosure |
|||||
B | C | |||||||
3 3 |
240 240 |
1 3 |
12 12 |
10 10 |
C-3041 C-3043 |
C-3041WXP C-3043WXP |
EC-3041 EC-3043 |
EC-3041WXP EC-3043WXP |
3 3 |
480 480 |
1 3 |
12 12 |
10 10 |
C-3051 C-3053 |
C-3051WXP C-3053WXP |
EC-3051 EC-3053 |
EC-3051WXP EC-3053WXP |
5 5 |
240 240 |
1 3 |
13 13 |
11 11 |
C-5041 C-5043 |
C-5041WXP C-5043WXP |
EC-5041 EC-5043 |
EC-5041WXP EC-5043WXP |
5 5 |
480 480 |
1 3 |
13 13 |
11 11 |
C-5051 C-5053 |
C-5051WXP C-5053WXP |
EC-5051 EC-5053 |
EC-5051WXP EC-5053WXP |
- Standard temperature range is 60°-250°F.
- For temperature range of 30°-110°F: add the suffix T1
- For temperature range of 200°-550°F: add the suffix T5
- For stainless steel header instead of brass header: add the suffix SSN. Consult Factory.
- Regulated models require a magnetic contactor for the following conditions:
- Single phase ampere rating over 30 amps
- All 208 and 240 volt, 3 phase applications.
- All 480V, single and three phase applications.
- 208V models not shown are available upon request. Consult factory.
- 240V units may be derated for 208V usage with a 25% reduction in wattage.